Escalator Technical specs
CZPT configuration | |
Inclination (°) | 30(35) |
Step width (mm) | 600/800/a thousand |
Horizontal methods | 2/two three/3(for 30°), 2/2 for 35° |
Velocity(m/s) | .5 |
Motor power | 8/eleven/15KW |
Handrail bracket | Stainless metal |
Rise height for 600 | 3000≤H≤6000/ 6000≤H≤7200 |
Rise height for 800 | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Rise height for 1000 | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Technologies Positive aspects
one.VVVF drive
two.Stable basic safety system
three.Excellent managing performance
4.Innovative handle program(German engineering)
5.Relaxed and efficient
six.Decrease noise and vitality-conserving
Protection Characteristics
1.Absence of phase, error stage security:
If deficiency of stage (relocating-walk) will or eror stage has been checked out, the escalator immediately cease the operation.
two.Motor more than-Ioad safety:
When the present exceeds fifteen% of the recent rating, the escalator will routinely slop the operation.
3.CZPTal appliance loop safety:
It gives the computerized circuit disconnecting device to shield the circuit and mains components of the escalator (relocating-walk).
4.Handrail inlet defense:
When some international substance has been clipped in the handrail inlet. the escalator (relocating-stroll) will instantly slop the operation.
5.Comb plate basic safety gadget:
When some international compound has been clipped in or amongst the combs.the escalator (transferring-walk) will routinely cease the procedure.
six.Phase sagging protection unit:
When there is irregular step bending, the escalator (moving-walk) will quit the procedure just before the action moving into into the comb plate
7.Damaged travel-chain safety unit:
When the drive-chain has been in excess of-stretched or it is damaged, the escalator (relocating-wander) will automatically quit the operation
8.Broken step chain defense:
When the action (plate) chain has been above-stretched or it is damaged, the escalator (relocating wander) will instantly slop the operation.
nine.In excess of-velocity protection:
When there is in excess of-speed to the escalator (moving walk),it will immediately cease the procedure.
ten.Course reversal defense:
When it will come the unintended reve rsal of the direction of journey, the escalator (relocating stroll) will instantly end the operation.
11.Security line:
The yellow synthetic resin safety line is found in the front place and two sides of the escalator tread so that the passengers will not tread in-amongst the edge of the adjacent step and the group lengthened skirt panel. The stability line on both sides of the action is greater than the tread floor. (The moving-wander offers the selective yellow spray-palmed stability line.)
About CZPT